Nano-etched fused-silica capillary used for on-line preconcentration and electrophoretic separation of bacteriophages from large blood sample volumes with off-line MALDI-TOF mass spectrometry identification

Warning

This publication doesn't include Faculty of Arts. It includes Faculty of Science. Official publication website can be found on muni.cz.
Authors

HORKÁ Marie KARÁSEK Pavel ŠALPLACHTA Jiří RŮŽIČKA Filip ŠTVERÁKOVÁ Dana PANTŮČEK Roman ROTH Michal

Year of publication 2020
Type Article in Periodical
Magazine / Source Microchimica Acta
MU Faculty or unit

Faculty of Science

Citation
Web https://link.springer.com/article/10.1007/s00604-020-4154-6
Doi http://dx.doi.org/10.1007/s00604-020-4154-6
Keywords Capillary electrophoresis; MALDI-TOF mass spectrometry; Nano-etched fused-silica capillary; Phage propagation; Staphylococcal bacteriophages; Supercritical water
Attached files
Description The properties of staphylococcal phages from the Siphoviridae, Podoviridae, and Myoviridae families were monitored using capillary electrophoretic methods on fused-silica capillaries with different morphology of surface roughness. Isoelectric points of the examined phages were determined by capillary isoelectric focusing in the original, smooth fused-silica capillary, and they ranged from 3.30 to 3.85. For capillary electrophoresis of phages, fused-silica capillaries with the "pock" and "cone" roughened surface types were prepared by etching a part of the capillary with supercritical water. The best resolution of the individual phages (to range from 3.2 to 4.6) was achieved with the "cone" surface-type fused-silica capillary. Direct application of phage K1/420 at the infection site, represented by human plasma or full blood spiked with Staphylococcus aureus, was on-line monitored by micellar electrokinetic chromatography. The phage particles were dynamically adhered onto the roughened surface of the capillary from 10 mu L of the prepared sample at the optimized flow rate of 6.5 mu L min(-1). The limit of detection was determined to be 10(4) phage particles. The linearity of the calibration lines was characterized by the regression coefficient, R-2 = 0.998. The relative standard deviation (RSD) of the peak area, calculated from ten independent measurements, was (+/-) 2%. After analysis, viability of the detected phages was verified by the modified "double-layer drop assay" method, and collected phage fractions were simultaneously off-line analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Graphical abstract