Alternative Reliable Method for Cytochrome P450 2D6 Poor Metabolizers Genotyping

Logo poskytovatele

Varování

Publikace nespadá pod Filozofickou fakultu, ale pod Středoevropský technologický institut. Oficiální stránka publikace je na webu muni.cz.
Autoři

PINDUROVÁ Eva ŽOURKOVÁ Alexandra ZRŮSTOVÁ Jana JUŘICA Jan PAVELKA Antonín

Rok publikování 2013
Druh Článek v odborném periodiku
Časopis / Zdroj Molecular Biotechnology
Fakulta / Pracoviště MU

Středoevropský technologický institut

Citace
www http://link.springer.com/article/10.1007%2Fs12033-012-9510-2
Doi http://dx.doi.org/10.1007/s12033-012-9510-2
Obor Genetika a molekulární biologie
Klíčová slova High resolution melting analysis; CYP2D6; poor metabolizers; SNP; short amplicon; melting curve
Přiložené soubory
Popis High-resolution melting curve analysis (HRM) of polymerase chain reaction (PCR) amplicons has been described as a fast, cheap and reliable closed-tube method of genotyping with no need for labeled primers or labeled probes. We adapted this melting analysis assay for the detection of the most common nonfunctional alleles of cytochrome P-450 (CYP) 2D6 in the Caucasian population that affect the metabolism of many commonly used drugs. We used this method to genotype 91 patients under paroxetine therapy. The presence and constitution of the most common single-nucleotide polymorphisms (1846G>A, 2988G>A, 100C>T, 2549delA, 2615_2617delAAG, 1707delT) in poor and intermediate metabolizers from the Caucasian population were detected in short amplicons 148 bp). After fluorescence normalization, the wild-type, homozygous and heterozygous samples were easily distinguishable from each other by their specific melting curve shape. A total of 92.6% of the 1846G>A heterozygotes, 96 % of the 100C>T heterozygotes and 100 % of the 2988G>A, 2549delA, 2615_2617delAAG and 1707delT heterozygotes have been correctly distinguished from the wild types. One hundred percent of all the homozygotes in this group of patients have been detected without any error. HRM of short amplicons is a simple tool for effective, rapid and reliable CYP2D6 genotyping that does not require real-time PCR, labeled probes, processing or any separations after PCR. The reaction is performed in a closedtube system and is highly specific and sensitive. We proved that this technique is highly reliable for use in routine diagnostics.
Související projekty:

Používáte starou verzi internetového prohlížeče. Doporučujeme aktualizovat Váš prohlížeč na nejnovější verzi.